  {"id":128,"date":"2017-04-19T16:14:31","date_gmt":"2017-04-19T16:14:31","guid":{"rendered":"https:\/\/www.vanderbilt.edu\/csb\/?page_id=128"},"modified":"2025-11-05T16:31:57","modified_gmt":"2025-11-05T22:31:57","slug":"cryo-electron-microscopy","status":"publish","type":"page","link":"https:\/\/www.vanderbilt.edu\/csb\/facilities\/cryo-electron-microscopy\/","title":{"rendered":"CSB Cryo-Electron Microscopy Facility"},"content":{"rendered":"<figure id=\"attachment_894\" aria-describedby=\"caption-attachment-894\" style=\"width: 294px\" class=\"wp-caption alignright\"><a href=\"https:\/\/cdn.vanderbilt.edu\/vu-URL\/wp-content\/uploads\/sites\/212\/2018\/08\/19171516\/ribo_cryo.jpg\"><img data-attachment-id=\"894\" data-permalink=\"https:\/\/www.vanderbilt.edu\/csb\/facilities\/cryo-electron-microscopy\/ribo_cryo\/\" data-orig-file=\"https:\/\/cdn.vanderbilt.edu\/vu-URL\/wp-content\/uploads\/sites\/212\/2018\/08\/19171516\/ribo_cryo.jpg\" data-orig-size=\"744,758\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"ribo_cryo\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;Ribosome&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/cdn.vanderbilt.edu\/vu-URL\/wp-content\/uploads\/sites\/212\/2018\/08\/19171516\/ribo_cryo-294x300.jpg\" data-large-file=\"https:\/\/cdn.vanderbilt.edu\/vu-URL\/wp-content\/uploads\/sites\/212\/2018\/08\/19171516\/ribo_cryo.jpg\" loading=\"lazy\" class=\"size-medium wp-image-894\" src=\"https:\/\/cdn.vanderbilt.edu\/vu-URL\/wp-content\/uploads\/sites\/212\/2018\/08\/19171516\/ribo_cryo-294x300.jpg\" alt=\"\" width=\"294\" height=\"300\" srcset=\"https:\/\/cdn.vanderbilt.edu\/vu-URL\/wp-content\/uploads\/sites\/212\/2018\/08\/19171516\/ribo_cryo-294x300.jpg 294w, https:\/\/cdn.vanderbilt.edu\/vu-URL\/wp-content\/uploads\/sites\/212\/2018\/08\/19171516\/ribo_cryo.jpg 744w\" sizes=\"(max-width: 294px) 100vw, 294px\" \/><\/a><figcaption id=\"caption-attachment-894\" class=\"wp-caption-text\">Ribosome<\/figcaption><\/figure>\n<p><span style=\"color: #ffffff\">placeholder text<\/span><\/p>\n<h4>Facility Overview<\/h4>\n<p>The <b>Center for Structural\u00a0Biology\u00a0Cryo-Electron Microscopy Facility\u00a0<\/b>houses\u00a0 cryo transmission electron microscopes for high resolution data collection of biological specimens by tomography and single-particle analysis.<\/p>\n<p>The <span style=\"text-decoration: underline\">Titan Krios G4<\/span> is the state-of-the-art 300kV microscope that combines equipment stability, enhanced automation and advanced software to aid researchers in efficient data collection. This microscope is equipped with a Volta phase plate, Gatan\u2019s <span style=\"text-decoration: underline\">BioQuantum energy filter<\/span>, <span style=\"text-decoration: underline\">K3 and Falcon3 direct electron detector<\/span> (DED) cameras and is computationally supported by multiple GPU workstations and a local 600TB RAID system. The <span style=\"text-decoration: underline\">Glacios<\/span> 200 kV microscope is equipped with a <span style=\"text-decoration: underline\">Falcon4i direct electron detector<\/span> and is capable of single particle, tomographic and MicroED applications.\u00a0 The <span style=\"text-decoration: underline\">L120C<\/span> 100kV TEM with Ceta-S 4k x 4k CMOS detector is used for screening and collecting images of negatively-stained specemins. The facility also has\u00a0two ThermoScientific <span style=\"text-decoration: underline\">Vitrobots<\/span>, one Leica <span style=\"text-decoration: underline\">EM GP2<\/span>, two carbon\/metal evaporators, glow discharge units and two <span style=\"text-decoration: underline\">Gatan 626<\/span> side-entry cryo sample holders.<\/p>\n<p>The microscopes are overseen by experienced staff who offer consultation and training in negative-stain and cryo sample preparation, single particle analysis, tomography, MicroED, data processing and additional computational support.<\/p>\n<p><strong>Visit the facility <a href=\"https:\/\/vanderbilt.corefacilities.org\/service_center\/5748\/\">iLab site<\/a> for equipment reservations, training and consultation requests. <a href=\"https:\/\/www.vanderbilt.edu\/csb\/pi-onboarding-information\/\">Click here<\/a> for information to set up an account for ACCRE and SBGrid.<br \/>\n<\/strong><\/p>\n<h4>Mission Statement<\/h4>\n<p>The goal of\u00a0the\u00a0<strong>CSB Cryo-EM Facility<\/strong> is to make TEM accessible to all interested researchers at Vanderbilt. TEM is one of the fastest developing, cutting-edge structural techniques for exploring the organization of biological macromolecules. The unique strength of TEM is its versatility. Structures determined using TEM can span resolution ranges from very low- to atomic-levels (&gt;30\u20131.8\u00c5) and do not require crystalline samples for analysis.<\/p>\n<p>In pursuit of its goal, the\u00a0<strong>CSB Cryo-EM Facility\u00a0<\/strong>enables TEM training and outreach by:<\/p>\n<ul>\n<li>Providing extensive training to new users.<\/li>\n<li>Providing advice and support in specimen preparation, data collection and image processing, computational image analysis, and structure determination.<\/li>\n<\/ul>\n<hr \/>\n<hr \/>\n<h3><a href=\"https:\/\/www.vanderbilt.edu\/csb\/cryo-em-contacts\/\" target=\"_blank\" rel=\"noopener noreferrer\">Contact us<\/a> to learn more about the\u00a0<strong>CSB Cryo-EM Facility<\/strong>.<\/h3>\n<h3>Check out our most recent <a href=\"https:\/\/www.vanderbilt.edu\/csb\/facilities\/cryo-electron-microscopy\/csb-cryoem-publications\/\" target=\"_blank\" rel=\"noopener noreferrer\">publications<\/a>.<\/h3>\n<hr \/>\n<hr \/>\n<h5><\/h5>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>placeholder text Facility Overview The Center for Structural\u00a0Biology\u00a0Cryo-Electron Microscopy Facility\u00a0houses\u00a0 cryo transmission electron microscopes for high resolution data collection of biological specimens by tomography and single-particle analysis. The Titan Krios G4 is the state-of-the-art 300kV microscope that combines equipment stability, enhanced automation and advanced software to aid researchers in efficient data collection. This microscope is&#8230;<\/p>\n","protected":false},"author":285,"featured_media":0,"parent":27,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"spay_email":""},"tags":[],"acf":[],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/pages\/128"}],"collection":[{"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/users\/285"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/comments?post=128"}],"version-history":[{"count":44,"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/pages\/128\/revisions"}],"predecessor-version":[{"id":6260,"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/pages\/128\/revisions\/6260"}],"up":[{"embeddable":true,"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/pages\/27"}],"wp:attachment":[{"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/media?parent=128"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.vanderbilt.edu\/csb\/wp-json\/wp\/v2\/tags?post=128"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}